Tripp Lite by Eaton EdgeReady™ Micro Data Center - 38U, (2) 3 kVA UPS Systems (N+N), Network Management and Dual PDUs, 230V Assembled/Tested Unit

  • Part: 1387726
  • Model: MDA2F38UPX00000
$10,481.00

Availability

Out of Stock

  • General Information
    • Manufacturer
    • Tripp Lite by Eaton
    • Manufacturer Website Address
    • https://tripplite.eaton.com/
    • Brand Name
    • Tripp Lite by Eaton
    • Product Type
    • UPS/Network Management/PDU Kit

Ship in Days, Not Weeks

Tripp Lite's EdgeReady™ micro data centers ship three business days after order receipt, assembled and tested. 40 base configurations are available for immediate order, or Tripp Lite's solutions team can customize every aspect of any base configuration to match your specific application. Customized solutions ship in as little as five business days.

Protect Edge Computing

Convenient and cost-effective EdgeReady™ micro data centers protect edge computing servers, storage and network hardware in locations where dedicated IT space is unavailable. Sites like branch offices, banks, retail locations, cell towers and factories often have little or no access to on-site IT staff, but they still require exceptional uptime for edge computing. Micro data centers require minimal space and support, yet provide availability comparable to a traditional data center.

Integrate Key Components

Base configurations combine a rack enclosure, UPS system, network management card, environmental/security sensor, power distribution unit (PDU), downloadable network management software, passive cooling and optional active cooling.

Save Time and Reduce Costs

Preconfigured IT infrastructure accelerates and standardizes installations for quick, easy, repeatable deployments and maintenance. Experienced solution experts design, validate, assemble and test solutions in a controlled environment to simplify orders, prevent configuration errors and reduce field costs. Reinforced shock pallets and torqued fittings stabilize shipment and support re-shipment from an intermediary configuration site.

Target Specific Applications

Tripp Lite offers 40 base configurations, and you can customize any model for your application. Options include active cooling, extended runtime, KVM switches, console servers, added security, airflow management, cable managers, power cords, network cables and patch panels. You can also upgrade the base PDU, rack or UPS.

Power Critical Systems

Two SmartOnline® UPS systems configured for N+N redundancy provide voltage- and frequency-independent (VFI) operation, expandable battery backup, zero transfer time and pure sine wave output. On-line double conversion isolates equipment from blackouts, brownouts, overvoltages, transients, surges, line noise, harmonic distortion, electrical impulses and frequency variations to prevent damage, downtime and data loss. Included battery capacity outlasts most power problems, and optional battery packs increase runtime. Two metered PDUs plug into the UPS systems to provide numerous outlets and digital current metering. Optional switched PDUs add remote current monitoring, threshold notifications and outlet control.

Manage from Any Location

A network management card provides monitoring, control and alerts via SNMP, Web, SSH or telnet. An environmental sensor monitors temperature, humidity and digital inputs. Free PowerAlert® Network Management System manages up to 250 units, or you can use your SNMP-compatible software of choice. Additional options include network-accessible KVM switches and console servers with fail-safe remote access.

Secure Equipment and Data

A PCI-compliant steel cabinet with EIA-standard mounting rails secures rack-mounted IT equipment. Doors and side panels lock to prevent unauthorized access, and an optional door-monitoring kit enables remote intrusion detection.

  • Warranty
    • Limited Warranty
    • 2 Year

  • Miscellaneous
    • Additional Information
    • OVERVIEW
      UPC Code 037332247162
      Rack Type Floor-Standing
      UPS Type On-Line
      PDU TypeMetered

      POWER
      Output Power Capacity (kVA) 3
      Output Power Capacity (Amps) 11.7
      Output Power Capacity (kW) 2.7
      Site Power Required (2) 230V, 13/16A, 50/60 Hz (2 Separate Circuits)
      Site Outlet Required BS 1363 (Standard) or CEE 7/7 "Schuko" (Optional)
      N+N Redundancy Yes

      COOLING
      Cooling Type Passive
      Cooling Type Details See Components List for active cooling options

      OUTPUT
      Output AC Waveform (AC Mode) Pure Sine wave
      Output AC Waveform (Battery Mode) Pure Sine wave
      Usable Outlets (UPS and PDU) (80) C13; (14) C19

      INPUT
      Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
      Input Phase Single-Phase
      Input Plug Type C20

      BATTERY
      Full Load Runtime (min.) 5 min.
      Half Load Runtime (min.) 13.5 min.
      Expandable Runtime Yes

      PHYSICAL
      Maximum Device Depth (in.) 37
      Rack Height 42U
      Usable Rack Space 38U
      Total Weight Capacity (lbs.) 3000
      Usable Weight Capacity (lbs.) 2555
      Unit Dimensions (hwd / in.) 78.5 x 23.63 x 43
      Shipping Form Factor Assembled/Tested Unit
      Unit Weight (lbs.) 445

      ENVIRONMENTAL

      Environmental Sensor E2MTHDI

      COMMUNICATIONS

      Network Management Cards (2) WEBCARDLX

      SPECIAL FEATURES
      High Availability UPS Features N+N Redundancy; On-Line (VFI) Operation; Auto Bypass; Battery Backup; Hot swappable batteries
      Acoustic Noise Suppression No

    • Package Contents
      • SR42UB Premium Rack Enclosure
      • 2 x SUINT3000LCD2U UPS Systems
      • 2 x P052-008 AC Input Cords with BS 1363 Plugs (UK)
      • 2 x WEBCARDLX Network Management Cards
      • E2MTHDI Environmental Sensor
      • 2 x PDUMV20HV Metered PDUs
      • 2 x P036-006 AC Input Cords
      • Owner's Manuals
    • Environmentally Friendly
    • Yes
    • Environmental Compliance
    • Restriction of Hazardous Substances (RoHS)
    • Country of Origin
    • China